茂港Design and calculation of industrial coolers

茂港

dustrial coolers,design

茂港

:本文围绕工业冷却器的设计与计算展开,阐述了工业冷却器在工业生产中的关键作用,其能有效地降低设备或工艺流程的温度,保障系统稳定运行,详细介绍了设计环节,包括依据不同的工业场景和冷却需求确定冷却器的类型,如风冷式、水冷式等,同时考虑冷却介质的特性、流量等参数,在计算方面,着重讲解了热负荷的计算方法,通过分析被冷却对象的热量产生速率、环境温度等因素,精准计算出所需的换热量,还涉及冷却器传热面积、传热系数等关键参数的计算,以确保冷却器能达到预期的冷却效果。

1、Design basis

茂港

茂港Design Standard for Steel Structures GB50017-2017Steel Structure Design Manual, China Construction Industry Press, January 2004

茂港

茂港Code for Construction and Acceptance of Steel Structures (GB50205-2020)

茂港

British Code for Design of Steel Structures (BS5950)

茂港2、Design load

Load includes structural self weight, wind turbine constant load, live load, snow load, wind load, etc. The structural calculation adopts the ultimate stress method, therefore, the load value is larger than usual. The surface load is calculated based on the distribution coefficient and applied to the platform according to the line load. The wind load is calculated based on the wind vibration coefficient, body shape coefficient, and basic wind pressure to calculate the wind pressure values on four surfaces, which are then converted into line loads and applied to the columns. Auxiliary components such as stair handrails are applied to the stairs according to uniformly distributed loads.

茂港

1. Constant load

茂港

The self weight of the steel structure is automatically calculated by the program, and the node weight is considered based on the self weight of the structure multiplied by 1.3. The weight and fluid load of the radiator are applied by external forces.

茂港

茂港Platform constant load: 0.50kN/m2

茂港2. Live load

茂港Live load of the platform for loading: 2.5kN/m2

茂港3. Snow load

茂港

According to relevant design data, the snow pressure can be basically calculated as 0.4N/m2.

茂港

茂港4. Wind load

茂港

Calculate according to the maximum value.

Basic wind pressure: 0.35kN/m2, height variation coefficient of 1.8, wind vibration coefficient: 1.5, ground roughness category: Class A

茂港

茂港Class.

茂港

Is the standard value of wind load, is the wind vibration coefficient at height Z, is the shape coefficient of wind load, and is the coefficient of wind pressure height variation.

When the standard value of wind load is less than 0.75kpa, calculate based on 0.75 kPa and multiply by 1.4 times the safety factor. Namely

茂港

5. Temperature load

The temperature difference is relatively small. The structural form is single, and the linear expansion of steel has a relatively small impact on the overall performance of the structure, which can be ignored.

茂港

6 Earthquake loads

茂港According to the seismic analysis design method: small earthquakes do not damage, medium earthquakes are repairable, and large earthquakes do not collapse. Small earthquake analysis can be divided into: bottom shear force method, response spectrum analysis, and elastic time history analysis. Medium earthquake analysis is calculated by multiplying small earthquake analysis by amplification factor.

Seismic fortification intensity: 8 degrees

茂港

Design basic seismic acceleration peak value: 0.3g

Construction site category: II site

茂港Design grouping: Second group

Damping ratio: 0.05

茂港

茂港This structure adopts MIADS software for overall modeling and analysis. During modeling, beam elements are mainly used for each structure. In order to facilitate loading, plate elements are established at the structural platform. Consolidation is used as the boundary condition at the bottom of each column, and constraints are applied at the connection between the column and the original structure according to the actual situation. The structure includes upright column, cross brace, slant support and upper and lower platform steel structure.

茂港

茂港Load sub factors and load combinations:

茂港

茂港Number

茂港

茂港load

茂港

茂港Partial    coefficient remarks

茂港

茂港Partial    coefficient remarks

1

茂港

dead load

1.3

茂港

茂港2

茂港

Dead load, when   it has a restraining effect on uplift and   overturning

茂港

茂港1.0

茂港

3

茂港

茂港Dead load, when   acting together with wind load and live load

茂港1.2

茂港4

茂港

茂港Live load

茂港

1.6

5

茂港Live load, when   combined with wind load

茂港1.2

茂港

6

茂港

Wind load

茂港

茂港1.4

7

茂港

茂港When combined   with wind load and live load

茂港

茂港1.2

茂港

茂港3、 Radiator calculation

茂港

茂港1. Material parameters

茂港Aluminum alloy adopts 6005-T1, with tensile strength and yield strength equivalent to 6063-T5, tensile strength ≥ 150Mpa, yield stress ≥ 110 Mpa. According to the performance table of aluminum alloy, it is found that 6063-T5 has a tensile strength of 185Mpa, yield stress of 145 Mpa, and fatigue strength of 90MPa.

茂港2. Working condition analysis

茂港The calculation of radiators can be divided into 1. lifting ondition,

茂港3. operating condition (operating condition is divided into

茂港

茂港4.support and lifting point participate in force simultaneously.

茂港

茂港5.support bears gravity, while lifting point bears horizontal force.

茂港6.support does not bear any force, that is, when the overall structure is subjected to uneven settlement, there is a suspension at the bottom)

茂港

茂港To ensure its stability, it is recommended that the foundation treatment should be pre compressed and settlement assessment should be carried out during the overall installation.

2.1 Hoisting conditions

At this point, the radiator is only considered for its own weight due to the lack of fluid injection, and is lifted and installed through a side lifting point. Because no other accessories were installed during modeling, in order to estimate the weight more accurately, its self weight coefficient was defined as 1.3.

茂港The radiator structure consists of 1, frame 2, support beam 3, heat exchange tube 4, tube plate, and other ancillary structures. As the heat exchange tube and support beam are fixed together through a corrugated plate, it can be considered that the heat exchange tube participates in the structural stress, which leads to strain and stress generation.

茂港The overall structural model is

茂港

茂港

Radiator structural model

茂港

茂港

茂港

The overall deformation of the radiator during the lifting process

茂港

茂港

茂港Stress cloud diagram of radiator during lifting process

茂港From its displacement cloud map, it can be seen that its overall deformation is 1.2mm, and the maximum stress is 15MPa

茂港Stress cloud map of heat sink

茂港

茂港

茂港

 

茂港

茂港Displacement cloud map of heat sink

From its displacement cloud map, it can be seen that its overall deformation is 1mm and the maximum stress is 2MPa. Through calculation, it can be seen that horizontal lifting has little effect on the heat dissipation fins, and its deformation and stress are far less than the standard requirements.

茂港

茂港The vertical lifting situation is as follows:

茂港

茂港

茂港

Vertical lifting stress cloud map

茂港

茂港